Main SP Tables-2
M160/M161 3-22 SM Appendix
2-930-012 HH:182 Lower E*
[0 to 70 / 52 / 1count/step]
Counter for judging the lower limit when
toner remaining in the developer
detected.
2-930-013 MM:182 Upper E*
[0 to 70 / 33 / 1count/step]
Counter for judging the upper limit
when toner remaining in the developer
detected.
2-930-014 MM:182 Lower E*
[0 to 70 / 48 / 1count/step]
Counter for judging the lower limit when
toner remaining in the developer
detected.
2-930-015 LL:182 Upper E*
[0 to 70 / 34 / 1count/step]
Counter for judging the upper limit
when toner remaining in the developer
detected.
2-930-016 LL:182 Lower E*
[0 to 70 / 46 / 1count/step]
Counter for judging the lower limit when
toner remaining in the developer
detected.
2-930-017 Sensor Standard V E*
[0.0 to 3.3 / 2.0 / 0.1V/step]
Threshold for judging the detection
result of toner end sensor.
2-930-018 Average Count E*
[0 to 255 / 0 / 1count/step]
Result of remaining detection in the
developer.
2-930-019 Self- Detection E
[- / - / -]
[Execute]
Detects forcibly the toner remaining in
the developer.
2-930-020 Self-Mixing Time E*
[0 to 300 / 10 / 1sec/step]
Required time for mixing prior to
forcibly execute remaining detection.