1. OUTLINE
IMR02L04-E3
1-6
Resistance temperature detector (RTD) input [voltage (low) group]
Type Code Measured range Code Measured range
Pt100
D21 200.0 to
200.0 C DB8 300.0 to 1200.0 F
D25 200.0 to
600.0 C DC9 328.0 to 1562.0 F
D34 100.00 to
150.00 C DD2 328 to 1562 F
D35 200.0 to
850.0 C
D36 200 to
850 C
JPt100
P10 0.0 to 500.0 C
P21 200.0 to
200.0 C
P26 200.0 to
600.0 C
P29 100.00 to
150.00 C
P30 200.0 to
640.0 C
P31 200 to
640 C
Voltage input, Current input
Type Code Voltage input group Measured range
Voltage 0 to 10 mV DC 101
Voltage (low) input group
Programmable range
Setting range: 19999 to 32000
[The decimal point position is selectable]
(Factory set value: 0.0 to 100.0)
Voltage 0 to 100 mV DC 201
Voltage 0 to 1 V DC 301
Voltage 0 to 5 V DC 401
Voltage (high) input group Voltage 0 to 10 V DC 501
Voltage 1 to 5 V DC 601
Current 0 to 20 mA DC 701
Current input group
Current 4 to 20 mA DC 801
Voltage 100 to 100 mV DC 901
Voltage (low) input group Voltage 1 to 1 V DC 902
Voltage 10 to 10 mV DC 903
Voltage 10 to 10 V DC 904
Voltage (high) input group
Voltage 5 to 5 V DC 905

Table of Contents

Other manuals for RKC INSTRUMENT PF900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RKC INSTRUMENT PF900 and is the answer not in the manual?

RKC INSTRUMENT PF900 Specifications

General IconGeneral
BrandRKC INSTRUMENT
ModelPF900
CategoryController
LanguageEnglish

Related product manuals