Remote Commands
R&S
®
FSW
733User Manual 1173.9411.02 ─ 19
The sweep list cannot be configured using remote commands during an on-going
sweep operation.
See also:
● CALCulate:LIMit:ESPectrum<sb>:PCLass<class>:LIMit[:STATe]
on page 752
[SENSe:]ESPectrum<sb>:HighSPeed.............................................................................. 733
[SENSe:]ESPectrum<sb>:RANGe<range>:BANDwidth[:RESolution]...................................734
[SENSe:]ESPectrum<sb>:RANGe<range>:BANDwidth:VIDeo............................................734
[SENSe:]ESPectrum<sb>:RANGe:COUNt?...................................................................... 734
[SENSe:]ESPectrum<sb>:RANGe<range>:DELete............................................................735
[SENSe:]ESPectrum<sb>:RANGe<range>:FILTer:TYPE................................................... 735
[SENSe:]ESPectrum<sb>:RANGe<range>[:FREQuency]:STARt........................................ 736
[SENSe:]ESPectrum<sb>:RANGe<range>[:FREQuency]:STOP......................................... 737
[SENSe:]ESPectrum<sb>:RANGe<range>:INPut:ATTenuation...........................................737
[SENSe:]ESPectrum<sb>:RANGe<range>:INPut:ATTenuation:AUTO.................................738
[SENSe:]ESPectrum<sb>:RANGe<range>:INPut:GAIN..................................................... 738
[SENSe:]ESPectrum<sb>:RANGe<range>:INPut:GAIN:STATe.......................................... 738
[SENSe:]ESPectrum<sb>:RANGe<range>:INSert............................................................. 739
[SENSe:]ESPectrum<sb>:RANGe<range>:LIMit<PClass>:ABSolute:STARt........................ 739
[SENSe:]ESPectrum<sb>:RANGe<range>:LIMit<PClass>:ABSolute:STOP......................... 740
[SENSe:]ESPectrum<sb>:RANGe<range>:LIMit<PClass>:RELative:STARt.........................740
[SENSe:]ESPectrum<sb>:RANGe<range>:LIMit<PClass>:RELative:STARt:ABS................. 741
[SENSe:]ESPectrum<sb>:RANGe<range>:LIMit<PClass>:RELative:STARt:FUNCtion..........742
[SENSe:]ESPectrum<sb>:RANGe<range>:LIMit<PClass>:RELative:STOP......................... 742
[SENSe:]ESPectrum<sb>:RANGe<range>:LIMit<PClass>:RELative:STOP:ABSolute........... 743
[SENSe:]ESPectrum<sb>:RANGe<range>:LIMit<PClass>:RELative:STOP:FUNCtion.......... 744
[SENSe:]ESPectrum<sb>:RANGe:LIMit<PClass>:STATe.................................................. 744
[SENSe:]ESPectrum<sb>:RANGe<range>:POINts:MIN[:VALue].........................................745
[SENSe:]ESPectrum<sb>:RANGe<range>:MLCalc........................................................... 745
[SENSe:]ESPectrum<sb>:RANGe<range>:RLEVel........................................................... 746
[SENSe:]ESPectrum<sb>:RANGe<range>:SWEep:TIME...................................................746
[SENSe:]ESPectrum<sb>:RANGe<range>:SWEep:TIME:AUTO.........................................747
[SENSe:]ESPectrum<sb>:RANGe<range>:TRANsducer....................................................747
[SENSe:]ESPectrum<sb>:HighSPeed <State>
This command turns high speed mode for SEM measurements on and off.
For more information including restrictions see chapter 5.6.4.3, "Fast SEM Measure-
ments", on page 203.
Suffix:
<sb>
.
1 | 2 | 3
Sub block in a Multi-SEM measurement
Parameters:
<State> ON | OFF
*RST: OFF