PLC-HP7000L Expand Serial Command Functional Specifications
28/94
8.5.9 CF_ORGMODE Command
Command
“CF_ORGMODE_%1” [CR]
%1
When input signal is PC Analog;
“VGA1” ------------------------ Specify VGA1
“VGA2” ------------------------ Specify VGA2
:
“XGA1” ------------------------ Specify XGA1
:
“WXGA3” --------------------- Specify WXGA3
“1080I60” --------------------- Specify 1080i60
“1080I50” --------------------- Specify 1080i50
“1035I” ------------------------ Specify 10350i
“720P60” --------------------- Specify 720p60
“720P50” --------------------- Specify 720p50
“575P------------------------- Specify 575p
“480P------------------------- Specify 480p
“575I” -------------------------- Specify 575i
“480I” -------------------------- Specify 480i
“1080PSF/24 ----------------- Specify 1080psf/24
“1080PSF/25 ----------------- Specify 1080psf/25
“1080PSF/30 ----------------- Specify 1080psf/30
“1080P24” -------------------- Specify 1080p24
“1080P25” -------------------- Specify 1080p25
“1080P30” -------------------- Specify 1080p30
“1080P50” -------------------- Specify 1080p50
“1080P60” -------------------- Specify 1080p60
* When input signal is not PC Analog, error code “101 is returned.
Details
After “EXT n” is set by PC control command such as CF_FSYNC/CF_TDOTS
and CF_SETPCADJ command, specify the signal originated with by issuing
this command.
This command is used to specify projector internal settings such as whether or
not to get PC signal through IP (Available only in the normal Power ON status)
Note; To differentiate between 60Hz and 50Hz in 1080i and 720p, “60” or 50
is necessary to add to the parameter in this command.
Acceptable “000” [CR]
Response
Unacceptable
“101” [CR] --- When input isn’t PC analog
8.5.10 CF_PCSTORE Command
Command
“CF_PCSTORE_%1 [CR]
%1
“1” --------------------------- Store current value of PC Adjust to Mode1
“2” --------------------------- Store current value of PC Adjust to Mode2
“3” --------------------------- Store current value of PC Adjust to Mode3
“4” --------------------------- Store current value of PC Adjust to Mode4
“5” --------------------------- Store current value of PC Adjust to Mode5
“6” --------------------------- Store current value of PC Adjust to Mode6
“7” --------------------------- Store current value of PC Adjust to Mode7
“8” --------------------------- Store current value of PC Adjust to Mode8
“9” --------------------------- Store current value of PC Adjust to Mode9
“10” ------------------------- Store current value of PC Adjust to Mode10
Details
Store current value of PC Adjust (each parameter status such as Total dots) to
Mode1-10. This command operates the same way as storing to Mode1-10 in
PC Adjust Menu.
(Available only in the normal Power ON status)
Acceptable “000” [CR]
Response
Unacceptable
“101” [CR] --- When input is Video signal
--- When input is no signal

Table of Contents

Other manuals for Sanyo PLC-HP7000L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLC-HP7000L and is the answer not in the manual?

Sanyo PLC-HP7000L Specifications

General IconGeneral
BrandSanyo
ModelPLC-HP7000L
CategoryProjector
LanguageEnglish

Related product manuals