EasyManuals Logo

Sanyo PLC-HP7000L Technical Specifications

Sanyo PLC-HP7000L
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
PLC-HP7000L Expand Serial Command Functional Specifications
73/94
9.7.10 CR_HMSLOT Command
Command
“CR_HMSLOT [CR]
Details Get the total number of Input.
Acceptable “000_%1” [CR]
%1
“004” ------------ When PJ-Net is attached.
“003” ------------ When PJ-Net is not attached.
Response
Unacceptable
“Error Code” [CR]
9.7.11 CR_NMSLOT1 Command
Command CR_NMSLOT1” [CR]
Details Get terminal information of Input1
Acceptable “000_%1” [CR]
%1 “RGB-HDMI”
Response
Unacceptable
“Error Code” [CR]
9.7.12 CR_NMSLOT2 Command
Command “CR_NMSLOT2” [CR]
Details Get terminal information of Input2
Acceptable “000_%1” [CR]
%1 5BNC”
Response
Unacceptable
“Error Code” [CR]
9.7.13 CR_NMSLOT3 Command
Command “CR_NMSLOT3” [CR]
Details Get terminal information of Input3
Acceptable “000_%1” [CR]
%1 “VIDEO”
Response
Unacceptable
“Error Code” [CR]
9.7.14 CR_NMSLOT4 Command
Command “CR_NMSLOT4” [CR]
Details Get terminal information of Input4
Acceptable 000_%1” [CR]
%1
NETWORK” -------- When PJ-Net is attached.
*With PJ-Net unattached, this command is invalid and error
code “103 is returned.
*With PJ-Net attached and the power OFF, error code “101
is returned.
*In models not supporting PJ-Net, error code “103” is
returned.
Response
Unacceptable
“Error Code” [CR]

Table of Contents

Other manuals for Sanyo PLC-HP7000L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLC-HP7000L and is the answer not in the manual?

Sanyo PLC-HP7000L Specifications

General IconGeneral
BrandSanyo
ModelPLC-HP7000L
CategoryProjector
LanguageEnglish

Related product manuals