EasyManuals Logo

Sanyo PLC-HP7000L Technical Specifications

Sanyo PLC-HP7000L
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
PLC-HP7000L Expand Serial Command Functional Specifications
46/94
8.9.20 CF_BLENDSTART Command
Command
“CF_BLENDSTART_%1_%2” [CR]
%1
“LEFT” ---------------------- Left side
“RIGHT -------------------- Right side
“TOP” ----------------------- Upper side
“BOTTOM” ---------------- Lower side
%2
“000”-“1024”-------------------- Directly specify value of direction of %1
*Value of upper limit changes by choice of %1
Left ---------------------- 000~0960
Right -------------------- 000~0960
Top ---------------------- 000~540
Bottom ----------------- 000~540
Details
Set the value of Start (Left/Right/Top/Bottom) for direction specified by Edge
blending %1. (Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.21 CF_BLENDBLK Command
Command
“CF_BLENDBLK_%1_%2” [CR]
%1
“R” ---------------------- Red
“G” ---------------------- Green
“B” ----------------------- Blue
%2 “-127” ~ “0127”-------------------- Directly specify value of color of %1
Details
Set value of color specified by Edge blending %1.
(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.22 CF_BLENDBLKALL Command
Command
“CF_BLENDBLKALL_%1” [CR]
%1
“UP” ------------------------------- Increment value of Black level(R/G/B) by 1
“DN” ------------------------------ Decrement value of Black level(R/G/B) by 1
Details
Set value of all of Black level of Edge blending.
(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.23 BLENDTESTPAT Command
Command
“CF_BLENDTESTPAT_%1” [CR]
%1
“ON” ---------------------- Set to On
“OFF” -------------------- Set to Off
Details
Set Test pattern of Edge blending.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.

Table of Contents

Other manuals for Sanyo PLC-HP7000L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLC-HP7000L and is the answer not in the manual?

Sanyo PLC-HP7000L Specifications

General IconGeneral
BrandSanyo
ModelPLC-HP7000L
CategoryProjector
LanguageEnglish

Related product manuals