PLC-HP7000L Expand Serial Command Functional Specifications
53/94
8.9.51 CF_ON-STA Command
Command
CF_ON-STA_%1” [CR]
%1
ON” --------------------------- Set Direct on active.
OFF” ------------------------- Set Direct on inactive.
UP” ---------- The same operation as pressing Up key or Left key
DN” ----------The same operation as pressing Down key or Right key
*”UP” and “DN” are exactly same operation.
Details
Set/Cancel Direct Power On (Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting value remains
effective even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.52 CF_POINTER Command
Command
“CF_POINTER_%1” [CR]
%1
“ARROW” ---------------------- Select Arrow Pointer
“FINGER” ---------------------- Select Finger Pointer
“LASER” ---------------------- Select Dot Pointer
Details
Select indication of Pointer. (Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting value remains
effective even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.53 CF_PTIMEMODE Command
Command
“CF_PTIMEMODE_%1” [CR]
%1
“COUNTUP” ---------------------- Set P-timer to Count up mode
“COUNTDN” ---------------------- Set P-timer to Count down mode
Details
Select count up/down mode of P-timer.
(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting value remains
effective even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.54 CF_PTIMER Command
Command
“CF_PTIMER_%1” [CR]
%1
“START” -------------------------- Start P-timer
“STOP” ---------------------------- Stop P-timer
“RESTART” ---------------------- Resume P-timer
“RST” ------------------------------ Reset P-timer
“EXIT” ----------------------------- Exit P-timer function
Details
Select the status of P-timer.
(Available only in the normal Power ON status)
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.55 CF_PTIME Command
Command
“CF_PTIME_%1” [CR]