PLC-HP7000L Expand Serial Command Functional Specifications
89/94
%1
“COUNTUP” -------------------- Set P-timer to Count up mode
“COUNTDN” -------------------- Set P-timer to Count down mode
Unacceptable
“Error Code” [CR]
9.10.45 CR_PTIMER Command
Command “CR_PTIMER” [CR]
Details Get setting status of P-timer
Acceptable “000_%a” [CR]
%1
“ON” -------------------- P-timer is activated
“STOP” ---------------- P-timer is temporarily suspended
“OFF” ------------------ Exit P-timer function
Response
Unacceptable
“Error Code” [CR]
9.10.46 CR_PTIME Command
Command “CR_PTIME” [CR]
Details Get setting time for count down mode of P-timer
Acceptable “000_%a” [CR]
%1 “001” – “180” ----------------------- 1 to 180 minutes
Response
Unacceptable
“Error Code” [CR]
9.10.47 CR_KEYDIS Command
Command “CR_KEYDIS” [CR]
Details Get status of RC/KEY (valid or invalid)
Acceptable “000_%1” [CR]
%1
“NONE” -------------------------- RC and KEY, both are valid
“RC” ------------------------------- RC is invalid
“KEY” ----------------------------- KEY is invalid
Response
Unacceptable
“Error Code” [CR]
9.10.48 CR_SECURITY Command
Command “CR_ SECURITY” [CR]
Details Get ON/OFF setting status of Security on menu.
Acceptable “000_%1” [CR]
%1
“ON” ------------ PJ is locked
“OFF” ----------- PJ is not locked.
Response
Unacceptable
“Error Code” [CR]
9.10.49 CR_PJLOCKNOW Command
Command “CR_PJLOCKNOW” [CR]
Details Get actual setting status of PIN code lock
Response Acceptable “000_%1” [CR]