PLC-HP7000L Expand Serial Command Functional Specifications
77/94
9.9 Lamp Status Read Command
9.9.1 CR_LAMPREPL Command
Command “CR_LAMPREPL” [CR]
Details Get information of Lamp Replacement time
Acceptable “000_%1” [CR]
%1
“1Y” ----------------- indicates over lamp replacement time
“1N” ----------------- indicates under lamp replacement time
Response
Unacceptable
“?” [CR]
9.9.2 CR_LAMPH Command
Command “CR_LAMPH” [CR]
Details
Get Lamp running time (in hours)
* return actual lamp running time
Acceptable “000_%1” [CR]
%1 “00000 - 99999”
Response
Unacceptable
“Error Code” [CR]
9.9.3 CR_LAMPCORRESPH Command
Command “CR_LAMPCORRESPH” [CR]
Details
Get Lamp running time (in hours)
*return lamp running time multiplied by a coefficient (not actual running time)
Acceptable “000_%1” [CR]
%1 “00000 – 99999”
Response
Unacceptable
“Error Code” [CR]
9.9.4 CR_LAMPMODE Command
Command “CR_LAMPMODE” [CR]
Details Get setting status of Lamp mode
Acceptable “000_%1” [CR]
%1
“NORMAL” --------------- Lamp mode is Normal status
“ECO1” -------------------- Lamp mode is Eco1 status
“ECO2” -------------------- Lamp mode is Eco2 status
“AUTO” -------------------- Lamp mode is Auto status
Response
Unacceptable
“?” [CR]
9.9.5 CR_LAMPSTS Command
Command “CR_LAMPSTS” [CR]
Details Get Lamp status
Acceptable “000_%1” [CR]
%1
“1I” ------------------------ Lamp is ON
“1O” ---------------------- Lamp is OFF
“1X” ----------------------- Lamp Failure
Response
Unacceptable
“Error Code” [CR]