EasyManuals Logo

Sanyo PLC-HP7000L Technical Specifications

Sanyo PLC-HP7000L
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
PLC-HP7000L Expand Serial Command Functional Specifications
54/94
%1 001” “180” -------------------------- Directly specify setting time
Details
Set the time for Count down mode of P-timer.
(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting value remains
effective even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.56 CF_KEYDIS Command
Command
“CF_KEYDIS_%1” [CR]
%1
“NONE” ----------------------- RC and KEY are both enabled.
“RC” ---------------------------- RC is disabled.
“KEY” -------------------------- KEY is disabled.
Details
Disable RC and/or KEY functions
(Available only in the normal Power ON status)
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.57 CF_PJPINCODE Command
Command
“CF_PJPINCODE_%1” [CR]
%1 0000 – 9999 ------------- Directly specify PJ PIN code
Details
Enter PIN code to cancel PIN code lock
(Available only in the normal Power ON status)
PIN code can not be changed. (Only PIN code lock is canceled.)
*When PIN code Lock is enabled:
PIN code is matched ------------------------- Command is valid (Acceptable)
PIN code is mismatched -------------------- Command is invalid (Error code “102”)
PIN code is beyond %1 available range ---- Command is invalid (Error code “?”)
*When PIN code lock is canceled:
PIN code is within %1 range ----------- Command is valid (Acceptable)
PIN code is out of %1 range ----------- Command is invalid (Error code is 102)
This command is only valid when “PJ PIN code” dialog is displayed to enter PIN
code after Power is ON and Countdown is completed.
When PIN code lock is set to “On1”, it needs to send this command every time
the projector is turned on.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.58 CF_SHUTPROT Command
Command “CF_SHUTPROT_%1” [CR]
%1
“OFF” ----------- RC and Side panel are both enabled.
“RC” ------------- RC is disabled.
“KEY” ----------- Side panel is disabled.
“BOTH” --------- RC and Side panel are both disabled.
Details
Set valid / invalid of Side panel or RC key on Shutter control function
(Valid only when in the normal Power ON status)
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]

Table of Contents

Other manuals for Sanyo PLC-HP7000L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLC-HP7000L and is the answer not in the manual?

Sanyo PLC-HP7000L Specifications

General IconGeneral
BrandSanyo
ModelPLC-HP7000L
CategoryProjector
LanguageEnglish

Related product manuals