PLC-HP7000L Expand Serial Command Functional Specifications
52/94
004” ------------------------------------ Select Code 4
005” ------------------------------------ Select Code 5
006” ------------------------------------ Select Code 6
007” ------------------------------------ Select Code 7
008” ------------------------------------ Select Code 8
UP” ---------- The same operation as pressing Up key or Left key
DN” ----------The same operation as pressing Down key or Right key
Details
Select Code of Remote Control (Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.48 CF_RSENS Command
Command
CF_RSENS_%1” [CR]
%1
“BOTH ---------------------- Select both front and back receiver of projector
FRONT” ------------------------------ Select only front receiver of projector
“BACK” ---------------------------- Select only back receiver of projector
UP” ---------- The same operation as pressing Up key or Left key
DN” ----------The same operation as pressing Down key or Right key
Details
Select location of infrared remote receiver of remote control
(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.49 CF_P-MANE Command
Command
CF_P-MANE_%1” [CR]
%1
OFF” ---------------------------------- Set Power Management to Off
READY1” ----------------------------- Set Power Management to Ready1
READY2” ----------------------------- Set Power Management to Ready2
“SHUTDOWN” --------------------- Set Power Management to Shut Down mode
UP” ---------- The same operation as pressing Up key or Left key
DN” ----------The same operation as pressing Down key or Right key
Details
Set/Cancel Power Management
(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.50 CF_P-MANETIME Command
Command
CF_P-MANETIME_%1” [CR]
%1
01” - ”30” ----- Directly specify setting time by the minute
UP” ------------ Increment value by 1 (Switched in 01→02→ --- → 30 → 01 order)
DN ------------ Decrement value by 1 (Switched in 30→29→ --- → 01 → 30 order)
Details
Set time of Power Management time
(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]