PLC-HP7000L Expand Serial Command Functional Specifications
86/94
9.10.29 CR_HDMI SETUP Command
Command
“CR_HDMI SETUP”[CR]
Details Get status of Image mode in HDMI setup
Acceptable 000_%1”[CR]
%1
“NORMAL” --------------------- Image mode is Normal
“ENHANCED” ----------------- Image mode is Enhanced
Response
Unacceptable
“Error code”[CR]
9.10.30 CR_FILREMAIN Command
Command “CR_FILREMAIN” [CR]
Details Get remaining number of usable Filter scroll
Acceptable 000_%1” [CR]
%1
09” = Remaining number of usable Filter scroll : 9 times
00” = Remaining number of usable Filter scroll : 0 time
Response
Unacceptable
“Error Code” [CR]
9.10.31 CR_FILH Command
Command “CR_FILH” [CR]
Details Get Filter used time
Acceptable 000_%1” [CR]
%1 00000 - 99999”
Response
Unacceptable
“Error Code” [CR]
9.10.32 CR_FILTIMER Command
Command “CR_FILTIMER” [CR]
Details Get Filter used time
Acceptable 000_%1” [CR]
%1
0400” ---------------------- Display massage by 400h used.
0700” ---------------------- Display massage by 700h used.
1000” ---------------------- Display massage by 1000h used.
OFF” ---------------------- Off(Warning display is not displayed)
Response
Unacceptable
“Error Code” [CR]
9.10.33 CR_FILCOND Command
Command “CR_FILCOND[CR]
Details Get status of filter clog
Acceptable 000_%1” [CR]
%1
CLOG” = Filter is clogged
“WARN” = Filter is nearly clogged
CLEAN” = Filter is not clogged
Response
Unacceptable
“Error Code” [CR]
9.10.34 CR_FILREPL Command
Command “CR_FILREPL” [CR]
Details Get status of Filter cleaning / replacement time

Table of Contents