PLC-HP7000L Expand Serial Command Functional Specifications
34/94
8.7.3 CF_VSCALE Command
Command
“CF_VSCALE_%1” [CR]
%1
“035” ---------------------- +35
“031” ---------------------- +31
:
“002” ---------------------- +2
“001” ---------------------- +1
“000” ---------------------- ±0
“‐01” ---------------------‐1
“‐02” ---------------------‐2
:
“‐31” ---------------------‐31
“‐32” ---------------------‐32
“UP” --------------------- Increment setting value of Vscale by 1
“DN” --------------------- Decrement setting value of Vscale by 1
Details
Set Vscale (Available only in the normal Power ON status)
*When the screen mode is not in “Custom”, projector changes image mode into
Custom by receiving this command.
*When there is no signal detected, projector returns 101 and the command does
not execute.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.7.4 CF_VPOS Command
Command
“CF_VPOS_%1” [CR]
%1
“015” --------------------- +15
“014” --------------------- +14
:
“002” --------------------- +2
“001” --------------------- +1
“000” --------------------- ±0
“‐01” ---------------------‐1
“‐02” ---------------------‐2
:
“‐14” ---------------------‐14
“‐15” ---------------------‐15
“UP” --------------------- Increment setting value of Vposition by 1
“DN” --------------------- Decrement setting value of Vposition by 1
Details
Set V Position (Available only in the normal Power ON status)
*When the screen mode is not in “Custom”, projector changes image mode into
Custom by receiving this command.
*When there is no signal detected, projector returns 101 and the command does
not execute.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]