13
Parameter setting
Parameterizing the communication and control unit "PFH-..."
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
179
Advanced configuration settings
For some CCU application modules, there are special settings, e.g. the interval of the
toggle bit for the SEWcontroller (line0).
Proceed as follows:
1. Open the configuration interface (→2176).
2. If you would like to change the settings for a certain CCU application module, click
on [2] at the end of the line for the associated axis.
18798219915
3. Specify the desired Settings and confirm with [Continue].
4. If you would like to change the settings for the entire process data range (all axes),
click on [1] in the axis area at the end of line 0 (SEW controller).
ð The following window is displayed.
18810225931
No. Description
[1] Enter the toggle bit interval in ms in this edit box.
[2] Select the byte swap of the process data from the fieldbus in this drop-down list:
• Off: Big-Endian (Motorola processors, such as in controllers by Siemens)
• On: Little-Endian (Intel processors, such as in controllers by Rockwell)
[3] In this drop-down list, you activate the MOVILINK
®
parameter channel:
• On: The MOVILINK
®
parameter channel is activated.
• Off: The MOVILINK
®
parameter channel is deactivated.
The MOVILINK
®
parameter channel enables bus-independent access to all
device parameters. Special services are available in this parameter channel to
be able to read different parameter information.
For detailed information, refer to the "Application Configurator for CCU" manual
16998413/EN – 12/2016