Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
226
P835 Response to "TF signal"
AUTO
Factory setting: No response
Triggered via the temperature sensor monitoring of the temperature sensor TF or TH
in the motor winding, as applicable.
P836 Response 'Timeout SBus1'
Factory setting: Emergency stop/malfunction
Triggered via the system bus timeout monitoring.
P838 Response 'SW limit switch'
Factory setting: Emergency stop/malfunction
This response is triggered if a target position outside the software limit switch is spe-
cified in the referenced drive. The software limit switches are set using parameters
P920/P921 SW limit switch CW/CCW (→2237).
P839 Response to "Positioning interruption"
Factory setting: No response
If the parameter P924 'Position interruption' detection (→2238) is activated, this re-
sponse is triggered upon interrupting a positioning process.
P84. Reset behavior
P840 Manual reset
Setting range: Yes/No
Set to "Yes": Resets the error in the power section "PFA-...". As soon as the reset
is carried out, the parameter automatically resets to the setting "No". Activating the
manual reset does not have any effect if there is no error present.
Set to "No": No reset is performed.