Assembly and Installation
FLOWSIC100 · Operating Instructions · 8012513/YSA5/V 2-1/2016-07 · © SICK Engineering GmbH 111
Subject to change without notice
Fig. 83 Impulse output
NOTICE:
I
max
(Open collector connection) may not exceed 100 mA. Otherwise the
impulse output can be destroyed.
Calculate R
L
according to the equation above.
Open collector (default setting) NAMUR
I
max
= 100 mA
1 k
1 k
10 k
+8,2 V DC
0 V
Vc 2V
01A
---------------------
R
L
Vc 2V
001A
---------------------
R
L
Vc