168 FLOWSIC100 · Operating Instructions · 8012513/YSA5/V2-1/2016-07 · © SICK Engineering GmbH
Specification
Subject to change without notice
6.2 Standard components
The standard components required for a complete measuring system depend on the
mechanical design of the sender/receiver unit. The following Table shows the possible
combinations and the quantities required:
1)
:The flange with tube or connection must be suitable for the sender/receiver unit
(see Flange with Tube Table)
2)
:Select the type depending on the internal duct pressure
3)
:Junction box optional for longer cable lengths
Sender/receiver unit Flange with
tube
1)
Connection cable
Junction
box
Control unit Purge air
unit
2)
Type Number
Master Slave
MCU-N MCU-P
FLSE100-M, H 2 2 1 1 1 1
FLSE100-PR 1 1
1
3)
1
FLSE100-SA/SD 1 each 2
1
3)
1
FLSE100-M-AC, HAC 2 2 1 1 1
1
FLSE100-PM, PH, PHS 2 2 1 1 1 1
1