Application range
1): The maximum possible measuring path depends on the dust content, gas temperature,
and gas composition
2): For extremely high dust concentrations up to max. 100 g/m³
3): For installation across secant (
p. 57, 3.1.3)
Type FLSE100
Material
Duct probe
Material
Transducer
Max. gas
temperature
[°C]
Active meas.
distance
1)
[m]
Duct/pipe
diameter [m]
M
SS, TI TI
260
0.2 - 4 0.15 - 3.4
Hastelloy 0.2 - 2 0.15 - 1.7
H
SS, TI TI
2 - 15 1.4 - 13
1.5 - 2.5
2)
1.1 - 2.5
3)
Hastelloy 2 - 5 1.4 - 4.3
PR
SS, TI
Tl
0.27 - 0.28 > 0.40
SA/SD
SS 150 0.2 - 2 0.15 - 1.7
MAC
SS, TI 450
0.2 - 4 0.15 - 3.4
HAC
2 - 13 1.4 - 11.3
1.5 - 2.5
2)
1.1 - 2.5
3)
PM
SS
450
0.5 - 3 0.35 - 2.5
PH
SS, TI
1 - 10 0.7 - 8.7
1 - 2
2)
0.7 - 2
3)
PHS
SS
2 - 13 1.4 - 11.3
1.5 - 2.5
2)
1.1 - 2.5
3)

Table of Contents