Control unit type key: MCU-X X X X X X X X X X X X X X
Integrated cooling air supply
- N: Without blower
- P: With blower
- C: Without blower + cooling air control option 24 V
- D: Without blower + cooling air control option 230 V
- E: With blower + cooling air control 24 V
Voltage supply
- W: 90 ... 250 V AC
- 2: Optional 24 V DC
Housing variant
- O: Wall enclosure compact, painted SICK orange,
stainless steel 1.4016 or equivalent
- R: 19“- housing
Display module
- N: Without
- D: With
Other options
- N: Without
Analog input option (plug-in module; 0/4...20 mA; 2 inputs per module)
- 0: Without
- n: With, n = 1. 2 2)
Analog output option (plug-in module; 0/4...22 mA; 2 outputs per module)
- 0: Without
- n: With, n = 1. 2 2)
Digital input option (plug-in module; 4 inputsper module)
- 0: Without
- n: Number on request
Digital output power option (plug-in module; 48 V DC, 5 A; 2 changeover contacts
per module)
- 0: Without
- n: Number on request
Digital output low power option (plug-in module; 48 V DC, 0.5 A; 4 NO contacts
per module)
- 0: Without
- n: Number on request
Optional Interface module
- N: Without
- B: T/P-MOD Ethernet V1,COLA-B, pulse 3)
- V: T/P-MOD Ethernet V1, COLA-B, 3-fold, pulse 3)
- Q: T/P-MOD Ethernet V2,MODBUS TCP, pulse 3)
- D: T/P-MOD RS485,MODBUS ASCII/RTU, pulse 3)
- F: T/P-MOD RS485,PROFIBUS, pulse 3)
Special features
- N: Without special version
Ex certification
- N: Without Ex certification