34 FLOWSIC600 · Technical Information · 8010125 V 4.0 · © SICK AG
Product Description
Subject to change without notice
Table 4 Hardware variant / output configuration with integrated Electronic Volume Corrector (EVC) continued
Hardware variant/Output configuration
1
1
X(Y/Z):
X = Code for hardware variant and output configuration within the new internal Key Code.
Y = Code for hardware variant within the Key Code (
pg. 207, Figure 97).
Z = Code for output configuration.
Analog board
Standard A (5/8) B(5/9) C(6/10) D(6/11)
Low
pressure
M (A/8) N (A/9) O (B/10) P (B/11)
Output terminal
31/32 EVC ext. PS EVC ext. PS EVC int. PS EVC int. PS
33/34 RS485 RS485 RS485 RS485
51/52 Pulse Pulse Pulse Pulse
41/42 Status Status Status Status
81/82 Status RS485 Status RS485