13 Technical data
13.1 Variant overview
Ordering information: see "Or
dering information", page 135.
Table 18: Devices and type codes
Performance package
Int
egration in the control
Protective field
range
Device without system
plug
System plug Device with system plug
•
C
ore
•
I/O AIDA
≤ 4.0 m MICS3-AAAZ40BZ1 MICSX-ABHZZZZZ1 MICS3-AAAZ40BZ1P01
≤ 5.5 m MICS3-AAAZ55BZ1 MICS3-AAAZ55BZ1P01
≤ 9.0 m MICS3-AAAZ90BZ1 MICS3-AAAZ90BZ1P01
13.2 Version numbers and functional scope
Functional scope
Older de
vices might not support the full functional scope of the latest Safety Designer.
To identify the different levels of the functionality, we use a 3-digit version number. The
version number is marked with the letter V on the device.
The functional scope of the device can be read at the following locations:
•
Label on the device
•
Display, entry in Device info menu at Hardware
•
Safety Designer, Overview dialog (only with connected device)
•
Safety Designer, report
Table 19: Functional scope of the microScan3 Core I/O AIDA
Version number Amendments and new functions
1.0.0
•
F
irst released version
1.1.0
•
N
ew rights management using user group Administrator (now 4
user groups)
•
Additional third option for resetting to factory settings
•
Modified process for resetting the password
•
Deviating multiple sampling after object detection can be con‐
figured
•
Interfaces and selected functions can be activated or deacti‐
vated
Revision
T
he different revision statuses of the devices are identified by “Rev” followed by a three-
digit version number. New devices have a label which indicates the revision status.
Table 20: Revision
Version number Amendments and new functions
1.0.0
•
F
irst released version
1.1.0
•
Internal change to components, no change in function
1.2.0
•
Int
ernal change to components, no change in function
1.3.0
•
Adaptation of detection behavior for optimized safety and avail‐
ability
In some cases, new system plugs are not suitable for older devices.
N
ew system plugs have a label which indicates the devices for which they are suitable.
TECHNICAL DATA 13
8017784/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
125