Page #66 background imageLoading...
Page #66 background image
User group Password Authorization
Authorized client Deactivated ex-works, i.e. it is
no
t initially possible to log on as
an authorized customer. The user
group can be activated by the user
group administrator and provided
with a password.
Ma
y read configuration from the
device.
May transmit verified and
unverified configuration to the
device.
May verify configuration.
Resetting the safety function
and communication settings to
factory defaults is allowed.
Change own password allowed.
Changing the password of the
Maintenance personnel user group
is allowed.
Administrator The password SICKSAFE is created
a
t the factory.
b
Change this password to pro‐
tect the device against unau‐
thorized access.
Ma
y read configuration from the
device.
May transmit verified and
unverified configuration to the
device.
May verify configuration.
Resetting whole device to fac‐
tory settings allowed.
Activating and deactivating
device functions is allowed.
Activating and deactivating the
Maintenance personnel and Author‐
ized client user groups is
allowed.
Change own password allowed.
Changing the passwords of
the Maintenance personnel and
Authorized client user groups is
allowed.
Complementary information
T
he maintenance engineer is permitted to reset the safety function to factory settings.
The configuration of the device is saved in the system plug. Therefore, the passwords
are retained when the device is replaced if the system plug is still used.
Further topics
"V
ersion numbers and functional scope", page 125
7.2.5 Settings
Information on the functionality and basic operation of the software and on the settings
in t
he main window can be found in the operating instructions of the Safety Designer
(part number 8018178).
7.2.6 Configuration
You collect the devices of a project in the Configuration area. The available devices can
be found in the Device Catalog. The devices are displayed as Device tiles in the working
range.
7 C
ONFIGURATION
66
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA 8017784/1ELL/2022-01-21 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Core I/O AIDA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Core I/O AIDA and is the answer not in the manual?

SICK microScan3 Core I/O AIDA Specifications

General IconGeneral
Scanning angle275°
Protection classIP65
Configuration methodSOPAS ET
Enclosure ratingIP65
Dimensions102 mm x 152 mm x 106 mm
Scanning range5.5 m
Protective field range5.5 m
Number of monitoring cases128
Supply voltage24 V DC
Performance levelPL e (ISO 13849-1)
Warning field range5.5 m
Resolution for safety field30 mm / 40 mm / 50 mm / 70 mm
Connection typeM12
Protective field resolution30, 40, 50, 70 mm