Reset When a protective device has sent a stop command, the stopped
s
tate must be maintained until a reset device is activated and the
machine can be restarted in a second step.
The reset brings the protective device back to the monitoring state
after it has sent a stop command. The reset also quits the start-up
or restart interlock of a protective device, so that the machine can
be restarted in a second step.
The reset must only be possible, when all safety functions and
protective devices are functional.
The reset of the protective device must not introduce any move‐
ment or dangerous situations itself. The machine is only permitted
to start after the reset once a separate start command has been
sent.
Manual resets are performed using a separate, manually oper‐
ated device, such as a reset pushbutton.
Automatic resets by the protective device are only permitted in
special cases, if one of the following conditions is met:
°
It must not be possible for people to be in the hazardous
area without triggering the protective device.
°
It must be ensured that no people are in the hazardous
area during or after the reset.
Resolution The resolution of an active opto-electronic protective device (also
k
nown as the sensor detection capability) is the minimum size of
an object for it to be reliably detected.
Response time The protective device’s response time is the maximum time
between the occurrence of the event leading to the sensor’s
response and supply of the switch-off signal to the protective devi‐
ce’s interface (for example OFF state of the OSSD pair).
Restart interlock The restart interlock prevents the machine from automatically
s
tarting up, for example after a protective device has responded
while the machine is operating or after changing the machine’s
operating mode.
The restart interlock can be implemented in the protective device
or in the safety controller.
A command to reset the protective device must be given, for
example using a reset pushbutton, before the machine can be
restarted.
Retroreflector A retroreflector reflects light back toward the light source largely
independentl
y of the alignment of the retroreflector.
Safety function Function of a machine whose failure can result in an immediate
increase of the risk(s). (ISO 12100)
Safety output A safety output provides safety-related information.
Safety outputs are OSSDs, for example, or safety-related informa‐
tion on a safety-related network.
Scan cycle time The scan cycle time is the time the sensor needs for a complete
sc
an of its detection area.
Example: Time required by the mirror of a safety laser scanner for
one rotation.
SIL Safety integrity level
SILCL SIL claim limit (IEC 62061)
Static control input A static control input is a dual-channel control input, which evalu‐
a
tes the status of every channel as the value 0 or 1. The signal
states of one or more static control inputs give a unique signal
pattern. This signal pattern activates a monitoring case.
17 GLOSSARY
140
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA 8017784/1ELL/2022-01-21 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Core I/O AIDA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Core I/O AIDA and is the answer not in the manual?

SICK microScan3 Core I/O AIDA Specifications

General IconGeneral
Scanning angle275°
Protection classIP65
Configuration methodSOPAS ET
Enclosure ratingIP65
Dimensions102 mm x 152 mm x 106 mm
Scanning range5.5 m
Protective field range5.5 m
Number of monitoring cases128
Supply voltage24 V DC
Performance levelPL e (ISO 13849-1)
Warning field range5.5 m
Resolution for safety field30 mm / 40 mm / 50 mm / 70 mm
Connection typeM12
Protective field resolution30, 40, 50, 70 mm
Number of protective fields128