6
Task list and notes
7.2.4 User groups
Overview
T
he devices contain a hierarchy of user groups that regulate access to the devices.
For certain actions (e.g., transferring a configuration to the device), you are requested
to log onto the device with the respective user group.
Depending on the device, 3 or 4 user groups are available.
Important information
NOTICE
W
hen you log into a device, the configuration software stores the password so that you
do not need to re-enter it for other configuration steps.
If you do not change any other settings in the login dialog, the password is deleted as
soon as you exit the configuration software, or log out in the main window or Device
window.
If you enable the Temporarily store password for login on additional devices. function, the
password will be retained even if you log out in the device window only.
If you leave the computer unattended, you must log off to prevent unwanted access to
the device.
Device with 3 user groups
T
able 5: User groups
User group Password Authorization
Operator Does not need a password (anyone
c
an log in as a machine operator).
Ma
y read configuration from the
device (if not blocked).
Maintenance
per
sonnel
Does not have a factory-set pass‐
word. The password is created by
the authorized client (namely, it is
not possible initially to log in as a
maintenance technician).
Ma
y read configuration from the
device.
May transfer verified configura‐
tion to the device.
Authorized client The password SICKSAFE is created
a
t the factory. Change this pass‐
word to protect the device against
unauthorized access.
Ma
y read configuration from the
device.
May transfer verified and
unverified configuration to the
device.
May verify configuration.
Can set a password for mainte‐
nance technicians.
Device with 4 user groups
T
able 6: User groups
User group Password Authorization
Operator No password required. Anyone can
lo
g on as a machine operator.
Ma
y read configuration from the
device.
Maintenance
per
sonnel
Deactivated ex-works, i.e. it is not
initially possible to log on as a
maintenance technician. The user
group can be activated by the user
group administrator and provided
with a password.
Ma
y read configuration from the
device.
May transmit verified configura‐
tion to the device.
Change own password allowed.
CONFIGURATION 7
8017784/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
65
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Core I/O AIDA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Core I/O AIDA and is the answer not in the manual?

SICK microScan3 Core I/O AIDA Specifications

General IconGeneral
Scanning angle275°
Protection classIP65
Configuration methodSOPAS ET
Enclosure ratingIP65
Dimensions102 mm x 152 mm x 106 mm
Scanning range5.5 m
Protective field range5.5 m
Number of monitoring cases128
Supply voltage24 V DC
Performance levelPL e (ISO 13849-1)
Warning field range5.5 m
Resolution for safety field30 mm / 40 mm / 50 mm / 70 mm
Connection typeM12
Protective field resolution30, 40, 50, 70 mm
Number of protective fields128