EasyManuals Logo

SICK microScan3 Core I/O AIDA User Manual

SICK microScan3 Core I/O AIDA
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #69 background imageLoading...
Page #69 background image
Project
Pr
oject name: the same name should be chosen for all devices in the project
Application name: this name can be the same for a number of devices in the
project. It highlights that these devices realize an application together, by respond‐
ing to one another for example.
Device information
N
ame, identifies the specific device
Type code of the safety laser scanner
Functional scope of the configuration in the project
Functional scope of the configuration in the device
Serial number of the safety laser scanner
Functionality of the device
Part number
Revision
Connection
C
onnection status
Type of connection
Checksums
A c
hecksum is used as a unique identification for a configuration. Using the checksum,
it is possible to work out whether a setup was changed or whether two devices have the
same configuration.
The checksum of the configuration in the project may not match the checksum in the
device, for example if a field geometry has been modified, but not yet transmitted to the
device.
System status
Applic
ation status
Current notification of the safety laser scanner
Configuration date for the configuration in the device
Synchronization: shows whether the configuration in Safety Designer and the con‐
figuration in the device are identical
Verification status of the configuration in the project
Verification status of the configuration in the device
Measurement data
S
hows the measurement data when a device is connected.
Display
S
hows the status of the display and LEDs when a device is connected.
Establishing connection
1.
Check whether the safety laser scanner is connected correctly.
2. Click on Connect in the toolbar.
Safety Designer establishes the connection to the safety laser scanner.
7.3.1 Functional scope
Older versions of the Safety Designer potentially do not support the full functionality of
the latest devices. Vice versa, older devices might not support the full functionality of
the latest Safety Designer.
CONFIGURATION 7
8017784/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
69
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Core I/O AIDA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Core I/O AIDA and is the answer not in the manual?

SICK microScan3 Core I/O AIDA Specifications

General IconGeneral
Scanning angle275°
Protection classIP65
Configuration methodSOPAS ET
Enclosure ratingIP65
Dimensions102 mm x 152 mm x 106 mm
Scanning range5.5 m
Protective field range5.5 m
Number of monitoring cases128
Supply voltage24 V DC
Performance levelPL e (ISO 13849-1)
Warning field range5.5 m
Resolution for safety field30 mm / 40 mm / 50 mm / 70 mm
Connection typeM12
Protective field resolution30, 40, 50, 70 mm

Related product manuals