Page #46 background image
190 mm
150 mm
S
L
Figure 31: Recommended fitting height
110 mm
150 mm
S
L
Figure 32: Recommended fitting height for inverted mounting
4.4 Integrating the equipment into the electrical control
This chapter contains important information about integration in the electrical control.
Inf
ormation about the individual steps for electrical installation of the device: see
"Electrical installation", page 59.
Information about pin assignment: see "Pin assignment", page 61.
Requirements for use
The output signals of the protective device must be analyzed by downstream controllers
in such a way that the dangerous state of the machine is ended safely. The signal is
analyzed with a safety controller.
4 PROJECT PLANNING
46
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA 8017784/1ELL/2022-01-21 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Core I/O AIDA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Core I/O AIDA and is the answer not in the manual?

SICK microScan3 Core I/O AIDA Specifications

General IconGeneral
Scanning angle275°
Protection classIP65
Configuration methodSOPAS ET
Enclosure ratingIP65
Dimensions102 mm x 152 mm x 106 mm
Scanning range5.5 m
Protective field range5.5 m
Number of monitoring cases128
Supply voltage24 V DC
Performance levelPL e (ISO 13849-1)
Warning field range5.5 m
Resolution for safety field30 mm / 40 mm / 50 mm / 70 mm
Connection typeM12
Protective field resolution30, 40, 50, 70 mm