Table 21: Compatibility
Label on the device Label on the system plug Compatible
Yes
Only compatible with Rev ≥ 1.1.0 Information is available
fr
om your SICK subsidiary.
Rev 1.1.0 (or higher) Yes
Rev 1.1.0 (or higher) Only compatible with Rev ≥ 1.1.0 Yes
13.3 Data sheet
13.3.1 microScan3 Core I/O AIDA
Features
T
able 22: Features
microScan3 Core I/O AIDA
Protective field range
Devices with a max. protec‐
t
ive field range of 4.0 m
≤ 4.0 m, details: see "Sensing range", page 133
Devices with a max. protec‐
t
ive field range of 5.5 m
≤ 5.5 m, details: see "Sensing range", page 133
Devices with a max. protec‐
tive field range of 9.0 m
≤ 9.0 m, details: see "Sensing range", page 133
Scanning range of the refer‐
ence contour field
Same as protective field range, see "Sensing range", page 133
Scanning range of the con‐
tour detection field
Same as protective field range, see "Sensing range", page 133
Distance measurement range
Devices with a max. protec‐
t
ive field range of 4.0 m
≤ 40 m
Devices with a max. protec‐
t
ive field range of 5.5 m
≤ 40 m
Devices with a max. protec‐
tive field range of 9.0 m
≤ 64 m
Fields ≤ 4
Simultaneously monitored
f
ields
≤ 4
Field sets ≤ 4
Monitoring cases 1
Scanning angle 275° (–47.5° … 227.5°)
Protective field resolution 30 mm, 40 mm, 50 mm, 60 mm, 70 mm, 150 mm, 200 mm
1)
Angular resolution
Devices with a max. protective field range of 4.0 m
Scan cycle time 30 ms 0.51°
Scan cycle time 40 ms 0.39°
Devices with a max. protective field range of 5.5 m
Scan cycle time 30 ms 0.51°
Scan cycle time 40 ms 0.39°
Devices with a max. protective field range of 9.0 m
13 TECHNICAL DATA
126
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA 8017784/1ELL/2022-01-21 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Core I/O AIDA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Core I/O AIDA and is the answer not in the manual?

SICK microScan3 Core I/O AIDA Specifications

General IconGeneral
Scanning angle275°
Protection classIP65
Configuration methodSOPAS ET
Enclosure ratingIP65
Dimensions102 mm x 152 mm x 106 mm
Scanning range5.5 m
Protective field range5.5 m
Number of monitoring cases128
Supply voltage24 V DC
Performance levelPL e (ISO 13849-1)
Warning field range5.5 m
Resolution for safety field30 mm / 40 mm / 50 mm / 70 mm
Connection typeM12
Protective field resolution30, 40, 50, 70 mm