c
ompliance with standards
°
correct use of the protective device
°
suitable configuration and safety function
°
correct alignment
The documentation matches the state of the machine, incl. the protective device
The verified configuration report corresponds to the desired project planning (see
"Verifying configuration", page 96)
The thorough checks must be carried out by qualified safety personnel or specially
qualified and authorized personnel and must be documented in a traceable manner.
In many cases, other data must be documented, see "Reports", page 98.
Recommended thorough checks
In man
y cases, it makes sense to carry out the following thorough checks during
commissioning and in certain situations:
Thorough check of the relevant points on the checklist, see "Checklist for initial
commissioning and commissioning", page 143
"Thorough visual check of the machine and the protective device", page 54
"Thorough check of the principal function of the protective device", page 53
"Thorough check of the area to be protected", page 53
"Test of the contour detection field", page 54
Make sure that the operating personnel has been instructed in the protective
device’s function before starting work on the machine. The instruction is the
responsibility of the machine operator and must be carried out by qualified per‐
sonnel.
4.5.2 Planning the regular thorough check
Overview
T
he purpose of regular tests is to detect defects due to changes or external influences
(e.g. damage or manipulation) and to ensure that the protective measure provides the
necessary protection.
Important information
DANGER
H
azard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of
non-observance.
b
Carry out tests at least once a year.
b
Assign qualified safety personnel to carry out the tests or persons specifically
authorized for this purpose.
b
Document tests in a traceable manner.
Minimum requirements
T
he following thorough checks must be carried out at least once a year:
"Thorough check of the principal function of the protective device", page 53
Testing of the detection capability (resolution) in the context of the "Thorough
check of the area to be protected", page 53
Recommendations for further thorough checks
In man
y cases, depending on the application conditions, the risk assessment of the
machine determines that further thorough checks are required or that some thorough
checks must take place more frequently.
4 P
ROJECT PLANNING
52
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA 8017784/1ELL/2022-01-21 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Core I/O AIDA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Core I/O AIDA and is the answer not in the manual?

SICK microScan3 Core I/O AIDA Specifications

General IconGeneral
Scanning angle275°
Protection classIP65
Configuration methodSOPAS ET
Enclosure ratingIP65
Dimensions102 mm x 152 mm x 106 mm
Scanning range5.5 m
Protective field range5.5 m
Number of monitoring cases128
Supply voltage24 V DC
Performance levelPL e (ISO 13849-1)
Warning field range5.5 m
Resolution for safety field30 mm / 40 mm / 50 mm / 70 mm
Connection typeM12
Protective field resolution30, 40, 50, 70 mm
Number of protective fields128