EasyManuals Logo

SICK microScan3 Core I/O AIDA User Manual

SICK microScan3 Core I/O AIDA
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #147 background imageLoading...
Page #147 background image
19 List of figures
1. Laser class 1M..............................................................................................................9
2. Device overview.......................................................................................................... 12
3. Principle of time-of-flight measurement....................................................................13
4. Light pulses scan an area.......................................................................................... 14
5. Protective field, shown in red in this document........................................................16
6. Reference contour field, shown in blue-green in this document.............................17
7. Hazardous area protection: detection of the presence of a person in the hazard‐
ous ar
ea...................................................................................................................... 18
8. Hazardous point protection: Hand detection............................................................18
9. Access protection: detection of a person when accessing a hazardous area........19
10. Mobile hazardous area protection: detection of a person when a vehicle
approaches................................................................................................................. 19
11. Prevent crawling beneath...........................................................................................21
12. Prevent stepping over.................................................................................................22
13. Unsecured areas.........................................................................................................23
14. Mounting with deflector plates (example).................................................................24
15. Mounting in an undercut (example).......................................................................... 24
16. Mounting in vehicle paneling (example)....................................................................25
17. Overrun of the protective field in front of an opening.............................................. 26
18. Tolerance band of the contour as reference field (protective field within the pro‐
tected opening, edge of the protected opening = reference contour).................... 27
19. Stationary application with horizontal scan plane for hazardous area protection.28
20. Protection against reaching over when mounted low (dimensions in mm)............ 31
21. Protection against reaching over when mounted high (dimensions in mm).......... 31
22. Scan plane at ankle height........................................................................................ 32
23. Scan plane at calf height........................................................................................... 33
24. Distance of the protective field from the wall...........................................................34
25. Stationary application in vertical operation for hazardous point protection.......... 35
26. Stationary application in vertical operation for access protection..........................38
27. Mobile application in horizontal operation for hazardous area protection.............41
28. flat-rate supplement ZF for lack of ground clearance..............................................42
29. Minimum supplement for lack of ground clearance................................................ 43
30. Stopping distance as a function of the vehicle’s speed...........................................44
31. Recommended fitting height..................................................................................... 46
32. Recommended fitting height for inverted mounting................................................ 46
33. Dual-channel and separate connection of the OSSDs of an OSSD pair.................49
34. No potential difference between load and protective device.................................. 50
35. Connection diagram with FE on the M12 plug connector....................................... 50
36. Connection diagram with FE on alternative FE connection..................................... 51
37. Prevent crawling beneath...........................................................................................57
38. Prevent stepping over.................................................................................................57
39. Mounting the safety laser scanner directly...............................................................58
40. Connection of the OSSDs of an OSSD pair...............................................................60
41. No potential difference between load and protective device ................................. 60
42. Pin assignment of the connecting cable (male connector, M12, 5-pin, A-coded). 61
43. Alternative FE connection.......................................................................................... 61
44. Software controls........................................................................................................64
45. Configuration...............................................................................................................67
46. Overview...................................................................................................................... 68
47. Functional scope.........................................................................................................70
48. Identification............................................................................................................... 71
49. Application.................................................................................................................. 73
50. Monitoring plane.........................................................................................................74
51. Reference contour field..............................................................................................78
LIST OF FIGURES 19
8017784/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
147
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Core I/O AIDA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Core I/O AIDA and is the answer not in the manual?

SICK microScan3 Core I/O AIDA Specifications

General IconGeneral
Scanning angle275°
Protection classIP65
Configuration methodSOPAS ET
Enclosure ratingIP65
Dimensions102 mm x 152 mm x 106 mm
Scanning range5.5 m
Protective field range5.5 m
Number of monitoring cases128
Supply voltage24 V DC
Performance levelPL e (ISO 13849-1)
Warning field range5.5 m
Resolution for safety field30 mm / 40 mm / 50 mm / 70 mm
Connection typeM12
Protective field resolution30, 40, 50, 70 mm
Number of protective fields128