DANGER
H
azard due to lack of effectiveness of the protective device
In the case of non-compliance, it is possible that the dangerous state of the machine
may not be stopped or not stopped in a timely manner.
b
Make sure that the following control and electrical requirements are met so the
safety laser scanner can fulfill its protective function.
A
restart interlock must be implemented depending on applicable national regula‐
tions or required reliability of the safety function. If a restart interlock is required, it
must be implemented in the external controller.
When using a safety controller, different signal levels of both OSSDs in an OSSD
pair must be detected depending on applicable national regulations or required
reliability of the safety function. The maximum discrepancy time tolerated by the
control must be selected according to the application.
In order to reach higher electromagnetic compatibility under rough electromag‐
netic ambient conditions, we recommend setting the input filter time of the con‐
nected control (on-off filter) to a value ≥ 5 ms. Please note that this increases the
response time of the total system by at least this set filter time.
The output signals from an OSSD pair must not be connected to each other.
In the machine controller, both signals from an OSSD pair must be processed
separately.
Figure 33: Dual-channel and separate connection of the OSSDs of an OSSD pair
T
he machine must switch to the safe state if, at any time, at least one OSSD in an
OSSD pair switches to the OFF state.
PROJECT PLANNING 4
8017784/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
49
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Core I/O AIDA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Core I/O AIDA and is the answer not in the manual?

SICK microScan3 Core I/O AIDA Specifications

General IconGeneral
Scanning angle275°
Protection classIP65
Configuration methodSOPAS ET
Enclosure ratingIP65
Dimensions102 mm x 152 mm x 106 mm
Scanning range5.5 m
Protective field range5.5 m
Number of monitoring cases128
Supply voltage24 V DC
Performance levelPL e (ISO 13849-1)
Warning field range5.5 m
Resolution for safety field30 mm / 40 mm / 50 mm / 70 mm
Connection typeM12
Protective field resolution30, 40, 50, 70 mm

Related product manuals