8 Commissioning
8.1 Safety
WARNING
H
azard due to lack of effectiveness of the protective device
b
Before commissioning the machine, make sure that the machine is first checked
and released by qualified safety personnel.
b
Only operate the machine with a perfectly functioning protective device.
DANGER
D
angerous state of the machine
During commissioning, the machine or the protective device may not yet behave as you
have planned.
b
Make sure that there is no-one in the hazardous area during commissioning.
DANGER
H
azard due to lack of effectiveness of the protective device
When changes are made to the machine, the effectiveness of the protective device may
be affected unintentionally.
b
After every change to the machine and changes to the integration or operational
and secondary conditions of the safety laser scanner, check the protective device
for effectiveness and recommission as specified in this chapter.
Before initial commissioning, project planning, mounting, electrical installation and
conf
iguration must be completed in accordance with the following chapters:
"Project planning", page 20
"Mounting", page 56
"Electrical installation", page 59
"Configuration", page 63
8.2 Alignment
The following options are available to you for precisely aligning the safety laser scanner
usin
g mounting kit 2:
COMMISSIONING 8
8017784/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
103
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Core I/O AIDA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Core I/O AIDA and is the answer not in the manual?

SICK microScan3 Core I/O AIDA Specifications

General IconGeneral
Scanning angle275°
Protection classIP65
Configuration methodSOPAS ET
Enclosure ratingIP65
Dimensions102 mm x 152 mm x 106 mm
Scanning range5.5 m
Protective field range5.5 m
Number of monitoring cases128
Supply voltage24 V DC
Performance levelPL e (ISO 13849-1)
Warning field range5.5 m
Resolution for safety field30 mm / 40 mm / 50 mm / 70 mm
Connection typeM12
Protective field resolution30, 40, 50, 70 mm
Number of protective fields128