Measurement method
Use e
very single distance value: Each scan of the surrounding contour is used individu‐
ally to draw the field.
Use median of distance values: The median of the last 25 scans is used to draw the
field.
Type of teach-in
Onl
y allow reduction: The shortest measured distance is used at each angle. If you
walk along the borders of the imaginary field and, e.g., hold a board or cardboard
into the laser beam, this restricts the surrounding contour.
Allow expansion: The surrounding contour is used as it is measured.
Automatic reduction
Y
ou can specify that the proposed field is drawn smaller than the measured surround‐
ing contour so that the field will be at a distance from walls. The default value corre‐
sponds to the TZ value (tolerance zone of the safety laser scanner).
Smoothing by point reduction
T
he proposed contour may initially be uneven and consist of very many points. With the
Smoothing by point reduction option, you can reduce the number of points and simplify the
lines.
CONFIGURATION 7
8017784/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
89
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Core I/O AIDA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Core I/O AIDA and is the answer not in the manual?

SICK microScan3 Core I/O AIDA Specifications

General IconGeneral
Scanning angle275°
Protection classIP65
Configuration methodSOPAS ET
Enclosure ratingIP65
Dimensions102 mm x 152 mm x 106 mm
Scanning range5.5 m
Protective field range5.5 m
Number of monitoring cases128
Supply voltage24 V DC
Performance levelPL e (ISO 13849-1)
Warning field range5.5 m
Resolution for safety field30 mm / 40 mm / 50 mm / 70 mm
Connection typeM12
Protective field resolution30, 40, 50, 70 mm

Related product manuals