Chapter 9 Operating instructions
S3000
120 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8009942/WK81/2012-11-28
Subject to change without notice
Commissioning
9 Commissioning
9.1 Initial commissioning
Commissioning requires a thorough check by qualified safety personnel!
Before you operate a system protected by the S3000 safety laser scanner for the first
time, make sure that the system is first checked and released by qualified safety
personnel. Please read the notes in chapter 2 “On safety” on page 11.
Prior to releasing the machine, check whether the access to the hazardous area is
completely monitored by the protective devices. Also check at regular intervals after
release of the machine (e.g. in the morning at the start of work) as to whether the S3000
correctly switches the OSSDs as soon as there is an object in the protective field. This
test should be performed along all protective field boundaries as per the specific
regulations for the application (see section 9.2 “Test notes” on page 121).
WARNING