Mounting
Observe the maximum tightening torque for the fastening screws on the S3000:
M6 on the rear = max. 12 Nm
M8 on the side = max. 16 Nm
The orientation in which the safety laser scanner is mounted is not relevant, i.e. you can
mount the S3000 both at an angle and upside down.
5.7.1 Direct mounting
The S3000 has four M6× 8 threaded holes on the rear. Using these holes you can mount
the S3000 directly if you can drill through the mounting surface from the rear.
The maximal tightening torque for the threaded holes is 12 Nm.
Use at least mounting kit 1. In this way the device will be easier to dismount.
5.7.2 Mounting with mounting kit 1
With the aid of mounting kit 1 you can mount the S3000 indirectly on the mounting
surface. This is always necessary if you cannot drill through the mounting surface from the
rear.
Mount the mounting kit 1 on the mounting surface.
Then mount the S3000 on mounting kit 1.
Pay attention to the maximum tightening torque for the threaded mounting holes M8×9
of 16 Nm.
Note
Note
Fig.
50
:
Threaded holes for
direct mounting
Recommendation
Fig.
51
:
Mounting with
mounting kit 1
M6
×
8
Fixing screws for the
S3000
Threaded mounting holes
M8
× 9
Mounting kit 1