Operating instructions Chapter 9
S3000
8009942/WK81/2012-11-28 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 121
Subject to change without notice
Commissioning
9.1.1 Power-up sequence
After switching on the S3000 runs through the power up cycle. During the power up cycle,
the 7<segment display indicates the device status.
During the initial commissioning of an S3000 the following indications are possible:
Step Display Meaning
1 , , , ,
, , ,
Power-up cycle, testing the 7<segment display. All
segments are activated sequentially.
2
or
Device addressed as host or guest
3 Power up cycle, during initial commissioning: device
in configuration mode
Other display Safety lock activated. Malfunction in external
conditions or in the device itself. See section 11.4
“Error and status indications on the 7<segment
display” on page 135.
Display
Meaning
Power-up cycle, step 1
Power-up cycle, step 2
Power-up cycle, step 3
Device status waiting for configuration
or object in the protective field,
OSSDs in the OFF state
Other display Safety lock activated. Malfunction in
external conditions or in the device
itself (see section 11.3 “Error and
status indications on the LEDs” on
page 133)
The duration of power up depends on the volume of the configuration data and can take
up to 20 seconds.
9.2 Test notes
The purpose of the tests described in the following is to confirm the safety requirements
specified in the national/international rules and regulations, especially the safety
requirements in the Machinery and Work Equipment Directive (EC conformity).
These tests are also used to identify if the protection is affected by external light sources
or other unusual ambient effects.
These tests must therefore always be performed.
Tab.
28
:
7>segment display
during and after the power
up sequence on initial
commissioning
Tab.
29
:
LED indication after
the power up sequence
Note