Chapter 5 Operating instructions
S3000
90 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8009942/WK81/2012-11-28
Subject to change without notice
Mounting
5.7.3 Mounting with mounting kit 2
With the aid of mounting kit 2 (only in conjunction with mounting kit 1) you can align the
S3000 in two planes. The maximum adjustment angle is ±11° in both planes.
Mount the mounting kit 2 on the mounting surface.
Then mount mounting kit 1 on mounting kit 2.
Then mount the S3000 on mounting kit 1.
Pay attention to the maximum tightening torque for the threaded mounting holes M8×9
of 16 Nm.
Adjust the S3000 longitudinally and cross-wise.
Fig.
52
:
Mounting with
mounting kit 2
Threaded mounting holes
M8
× 9
Fixing screws for the
S3000
Mounting kit 1
Mounting kit 2