Maintenance and care
10 Maintenance and care
Do not make any repairs to the device!
The S3000 does not contain any repairable components. For this reason do not open the
S
3000 components and only replace the parts that are described in the following chapters
as replaceable.
Switch the entire machine/system off line!
The machine/system could inadvertently start up while you are changing the front screen.
As a matter of principle, always isolate the machine from the power supply during all work
on the machine and safety laser scanner.
10.1 Cleaning the front screen
The S3000 safety laser scanner is largely maintenance-free. The front screen on the safety
laser scanner should however be regularly cleaned and also if contaminated.
Do not use aggressive cleaning agents.
Do not use abrasive cleaning agents.
Static charges cause dust particles to be attracted to the front screen. You can diminish
this effect by using the anti-static plastic cleaner (SICK part no. 5600006) and the SICK
lens cloth (part no. 4003353) (see section 13.3 “Accessories/spare parts” on
page 163).
How to clean the front screen:
Use a clean and soft brush to remove dust from the front screen.
Moisten the SICK optics cloth with the anti-static plastic cleaner and wipe off the front
screen with the cloth.
10.2 Replacing the front screen
Always perform a front screen calibration after the replacement of the front screen!
After the replacement of the front screen with a new front screen you must perform a front
screen calibration with the aid of the CDS. In this way the new front screen on the S3000
is measured and the device made functional. Perform the front screen calibration at room
temperature.
If the front screen is scratched or damaged, you must replace it. Order the replacement
front screen from SICK (see section 13.3 “Accessories/spare parts” on page 163).
The front screen on the S3000 is an optical part that must not be contaminated or
scratched on replacement.
The front screen is only allowed to be replaced by qualified safety personnel in a dust-
and dirt-free environment.
Never replace the front screen during operation as dust particles could enter the device.
It is imperative that you avoid contamination of the inside of the front screen, e.g. with
fingerprints.