Operating instructions Chapter 6
S3000
8009942/WK81/2012-11-28 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 101
Subject to change without notice
Electrical installation
6.3 Pre-assembled system plugs
6.3.1 Pre-assembled system plugs with flying leads
To connect the S3000 variants, the following pre-assembled system plugs are available
(see also section 13.3.4 “System plug” on page 164):
SX0A-B0905G
– for S3000 Standard and S3000 Remote
– with 9 unscreened cores
– 5 m long
– cable outlet on the bottom
SX0A-B0905B, SX0A-B0910B and SX0A-B0920B
– for S3000 Standard and S3000 Remote
– with 9 unscreened cores
– 5, 10 or 20 m long
– cable outlet on the top
SX0A-B1305B, SX0A-B1310B and SX0A-B1320B
– for S3000 Advanced
– with 13 unscreened cores
– 5, 10 or 20 m long
– cable outlet on the top
SX0A-B1305D and SX0A-B1310D
– for S3000 Professional and S3000 Expert with static and dynamic inputs
– with 13 unscreened cores
– 5 or 10 m long
– with 3 M12 cable entries for incremental encoders
– cable outlet on the top
SX0A-B1705B, SX0A-B1710B and SX0A-B1720B
– for S3000 Professional and S3000 Expert with static inputs
– with 17 unscreened cores
– 5, 10 or 20 m long
– cable outlet on the top