Page #31 background imageLoading...
Page #31 background image
Operating instructions Chapter 3
S3000
8009942/WK81/2012-11-28 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 31
Subject to change without notice
Product description
3.5.2 Interoperability of the variants
Due to the further development of the safety laser scanner, additional functions, e.g. triple
field technology, have been implemented in the device. As a result the latest devices are
not 100% compatible with safety laser scanners already in use in the field.
To ensure compatibility, the S3000 safety laser scanners with firmware J B02.41 and
serial number > 12210000 can be operated in compatibility mode. The following tables
show which devices can form an EFI system.
Interoperability with safety laser scanners
S3000
Standard
S3000
Advanced
S3000
Professional
S3000
Remote
S3000
Expert
S300
Standard
S300
Advanced
S300
Professional
S300 Expert
S300 Mini
Standard
10)
S300 Mini
Remote
S3000 Standard  X
S3000 Advanced  X
S3000 Professional  X
S3000 Remote 
9)
 X
9)
S3000 Expert  X
Tab. 4: Interoperability with safety laser scanners
= EFI system possible
X = EFI system not possible
Interoperability with safety laser scanners in compatibility mode
(see section 4.1 on page 33)
S3000 Standard
S3000 Advanced
S3000
Professional
S3000
Professional CMS
S3000 Remote
S3000 Expert
S300 Standard
10)
S300 Advanced
S300 Professional
S300 Professional
CMS
S300 Expert
S300 Expert CMS
S300 Mini
Standard
10)
S300 Mini Remote
S3000 Standard  X  XX
S3000 Advanced  X  XX
S3000 Professional  X  XX
S3000 Remote 
9)
X  XX
S3000 Expert  X  XX
Tab. 5: Interoperability with safety laser scanners in compatibility mode
= EFI system possible
X = EFI system not possible
9)
Only in combination with Flexi Soft safety controller or sens:Control device.
10)
Device does not have an EFI interface, for this reason an EFI system is not possible.