Operating instructions Chapter 6
S3000
8009942/WK81/2012-11-28 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 97
Subject to change without notice
Electrical installation
6.1.1 Pin assignments of the I/O modules
Pin Signal Function
Standard
Advanced
Professional
Expert
Remote
1 +24 V DC Supply voltage S3000
2 0 V DC Supply voltage S3000
3
OSSD1 Output signal switching device
4 OSSD2 Output signal switching device
5 RESET Input, Reset
6 EDM Input, external device monitoring
7 UNI<I/O1/
ERR
Universal I/O and application
diagnostic output or connection for a
jumper for addressing as guest
21)
8 UNI<I/O2/
RES_REQ
Universal I/O or output for Reset
required
9 UNI<I/O3/
WF
Universal I/O or output for Object in
warning field
10 A1 Static control input A or connection
for a jumper for addressing as
guest
21)
22)
22)
11 A2 Static control input A
12 B1 Static control input B
13 B2 Static control input B
14 EFI
A
15 EFI
B
Enhanced function interface =
safe SICK device communication
16 +24 V DC
17 GND
Supply voltage incremental encoder 1
18 C1 or
INC1_0
Static control input C or dynamic
control input (incremental encoder
input) 1
19 D1 or
INC1_90
Static control input D or dynamic
control input (incremental encoder
input) 1
20 +24 V DC
21 GND
Supply voltage incremental encoder 2
22 C2 or
INC2_0
Static control input C or dynamic
control input (incremental encoder
input) 2
21)
In an EFI system, a device must be defined as a guest using a jumper between pin 7 and pin 10. This is also
necessary if several safety laser scanners are connected to one EFI string on a Flexi Soft safety controller.
22)
No control input A on S3000 Standard and Remote.
of the I/O modules