Operating instructions Chapter 4
S3000
8009942/WK81/2012-11-28 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 63
Subject to change without notice
Configurable functions
On the S3000, a multiple sampling of 2 is the minimum setting. You can set the multiple
s
ampling up to 16 with the aid of the CDS. The supplement to the basic response time
resulting from your setting is displayed in the CDS.
Recommended multiple sampling
Application Basic response time 60 ms Basic response time 120 ms
Stationary under clean
ambient conditions
2 times 2 times
Vertical applications 3 times –
Mobile 4 times 4 times
Stationary under dusty
ambient conditions
8 times 8 times
Using multiple sampling you can increase the availability of a system.
You can configure the multiple sampling in the CDS. You can set individual multiple
sampling both for the field set defined and for the simultaneous field set in each
monitoring case.
4.10.5 Simultaneous monitoring
On the S3000, simultaneous monitoring can only be configured in the dual field mode or
in the dual protective field mode (see Fig. 5 on page 20).
Using simultaneous monitoring, the S3000 can monitor two field sets simultaneously (e.g.
hazardous area on the left and hazardous area on the right) within a monitoring case.
For this purpose choose on the Resolution/field mode tab (see section 4.3.4 “Field
mode” on page 39) either the Dual or Dual protective fields field mode.
Then, on the Resolution/field mode tab select the Simultaneous field evaluation
option.
If you evaluate the status of the protective fields using Flexi Soft, then on the
Resolution/field mode tab first select the Transfer unallocated fields as infringed
option.
If you have selected the Dual protective fields field mode, then the Transfer
unallocated fields as infringed option is selected automatically.
Then choose on the Cases tab a further field set as a simultaneous field set within the
related monitoring case.
On a system with one S3000 the first protective field in both field sets acts on the internal
OSSDs in the S3000. In a system with several devices connected via EFI, the both field
sets can act on different OSSDs (see section 4.6 on page 46).
You configure a monitoring case with simultaneous field set in the CDS.
multiple sampling
Recommendation
Note