EasyManua.ls Logo

SICK S3000

SICK S3000
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating instructions Chapter 4
S3000
8009942/WK81/2012-11-28 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 51
Subject to change without notice
Configurable functions
4.8.1 Application diagnostic output in the compatibility mode
The S3000 variants have a configurable application diagnostic output in the compatibility
mode. For the application diagnostic output you configure in the CDS …
whether it is deactivated.
whether a signal is only output when the front screen is contaminated.
whether a signal is only output on errors.
whether a signal is output both for front screen contamination and on errors.
4.9 Field sets
The number of field sets that can be configured is dependent on the safety laser scanner
variant.
On the S3000 Expert and S3000 Remote the number of field sets that can be configured
is also dependent on the field mode selected (dual field mode/dual protective field mode/
triple field mode) and the angular resolution configured. The following table shows the
number of field sets per variant and application:
Standard Advanced Professional Expert Remote
Dual field mode/dual protective field mode
Configured angular resolution 0.5°
1 4 8 32 32
Configured angular resolution 0.25°
1 4 8 16 16
Triple field mode
Configured angular resolution 0.5°
1 4 8 21 21
Configured angular resolution 0.25°
1 4 8 10 10
Tab.
15
:
Number of field sets
that can be configured per
variant and use

Table of Contents

Other manuals for SICK S3000

Related product manuals