Chapter 10 Operating instructions
S3000
128 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8009942/WK81/2012-11-28
Subject to change without notice
Maintenance and care
If the front seal is not inserted correctly, the front screen may be damaged. Do not use any
pointed or sharp tools.
First place the seal only lightly in the rounded sections of the seal groove. In this way you
will avoid stretching the seal.
Only then press the seal home. The seal should not be stretched on insertion.
The seal is pressed in far enough when the edge of the seal and the sensor head are flush.
It is imperative that you check that the seal is seated evenly all the way around the
groove.
Check whether the mirror on the motor is clean and remove any contamination with an
optic brush.
Set a torque wrench to 0.7 Nm (hand-tight) and have this to hand.
Take the new front screen from the packaging.
Remove any remnants of packaging.
Place the front screen on the rubber seal and insert the new fixing screws to with
spacers (see Fig. 90).
Press the front screen on the front of the cover. During this process tighten the front
screws to to the tightening torque set.
Then insert the rest of the screws to with spacers (see Fig. 90), and tighten using
the torque wrench.
Re-commissioning the S3000:
Correctly re-mount the S3000 (see chapter 5 “Mounting” on page 66).
Connect the S3000 system plug.
After power up the S3000 automatically reads the saved configuration from the system
plug (see section 9.3 “Re-commissioning” on page 124).
Always perform a front screen calibration with the aid of the CDS after the replacement
of the front screen!
The level of contamination is measured continuously during the operation of the S3000.
For this purpose the front screen calibration must first be performed; this then serves as a
reference for the contamination measurement (status = not contaminated).
The front screen calibration may only be performed immediately after the replacement of
the front screen!
The new front screen must be free of contamination at the time of the front screen
calibration. The front screen calibration should be performed at room temperature
(10<30 °C)!
Note
Fig.
91
:
Depth for pressing in
the seal
WARNING
Seal edge flush with
housing edge
Seal
Housing