Chapter 5
Setup and Configuration
RUGGEDCOM WIN
User Guide
62 Disconnecting from Specific Base Stations
2
1
3 4
6
7
8
5
Figure54:Allowed BS Screen
1.Connect only to allowed BS List 2.Allowed BS List Table 3.Add Button 4.Delete Button 5.Connect only to allowed
Operator ID Box 6.Apply Button 7.Connect Button 8.Disconnect Button
3. Set the Connect only to allowed BS option box to Enable.
4. Select a base station ID from the Allowed BS List table.
5. Click Connect.
Section5.3.5
Disconnecting from Specific Base Stations
The Allowed BS List table provides a list of specific base stations to connect to. When the device is connected to
these base stations, clicking Disconnect disconnects the RUGGEDCOM WIN from all base stations the device is
currently connected to.
CAUTION!
Connection Loss Hazard - Risk of data loss or failure of functioning processes. Clicking Disconnect
while using the RF interface will stop the RUGGEDCOM WIN from transmitting and the RUGGEDCOM
WIN will lose its connection to the base station(s). A hard reset (shutting down and then powering
up) or a site visit will be required to reboot the RUGGEDCOM WIN using the GUI. Before clicking
Disconnect, make sure you are not using the RF Interface.
To disconnect from base stations, do the following:
1. Navigate to WiMAX» Allowed BS. The Allowed BS screen appears.

Table of Contents

Other manuals for Siemens RUGGEDCOM WIN5123

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM WIN5123 and is the answer not in the manual?

Siemens RUGGEDCOM WIN5123 Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM WIN5123
CategoryWireless Router
LanguageEnglish

Related product manuals