RUGGEDCOM WIN
User Guide
Chapter 5
Setup and Configuration
Configuring Traps 75
Event Name Description
DuplicateNsiIp Duplicate LAN IP address.
DuplicateRfiIp Duplicate RF IP address.
CPELocked
The SS Ethernet port is locked to forward user data.
Only management data is permitted from the LAN.
CPEUnlocked The SS Ethernet port is unlocked to forward user data.
ACLPacketDrop
If the maximum permitted number of access list
entries is exceeded, packets from any new host will
be dropped. In addition to a trap being sent at the
occurence, the trap will be sent every 1000 packets.
Section5.12.2.4
Configuring Traps
To configure traps, do the following:
1. Navigate to Management» Alarms and Traps» Traps. The SNMP Trap Settings screen appears.
Figure68:SNMP Trap Settings
2. Configure the following parameter(s) as required:
Parameter Description
Trap ID Displays the trap identification number.