EasyManua.ls Logo

Siemens SIMATIC NET - Page 109

Siemens SIMATIC NET
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Examples of applications
3.2 Redundantly coupled networks
Industrial Ethernet
System Manual, 09/2019, C79000-G8976-C242-10
109
router. Because the virtual addresses are used unchanged, the ARP table must not be
updated when the master router is changed.
The two connection paths to the production network between the devices
and as well
as
and are managed by means of s suitable routing protocol, such as OSPF.
Each automation cell is protected through a security communication processor (for example,
SIMATIC CP 1543-1) or an Industrial Security Appliance (for example, SCALANCE SC646-
2C).
Benefits
Extremely high reliability through redundant coupling of the networks
High data throughput through 10 Gbps technology of the SCALANCE XR552-12M used
in the production network
Separation of networks through a firewall

Table of Contents

Other manuals for Siemens SIMATIC NET

Related product manuals