SCALANCE network components
4.7 SCALANCE M industry router
Industrial Ethernet
System Manual, 09/2019, C79000-G8976-C242-10
249
4.7.3.2 Features and functions
Features
The individual devices have the characteristics shown in the following table:
M874-2 2.5G
M874-3 3G
M876-3 3G
M876-3 3G (ROK)
M876-4 LTE (EU)
M876-4 LTE (NAM)
Supported wireless networks GSM GSM
UMTS
GSM
UMTS
CDMA *
EV-DO *
GSM
UMTS
LTE
Supported mobile wireless services GPRS
eGPRS
GPRS
eGPRS
HSPA+
GPRS
eGPRS
HSPA+
GPRS
eGPRS
HSPA+
LTE Cat. 3
Ethernet interface
2x RJ45
2x RJ45
4x RJ45
4x RJ45
Transmission rate 10/100 Mbps
Number of SMA antenna sockets
1
1
2
2
Power supply 24 V DC
Redundant power supply
C-PLUG slot
Digital input/output
1/1
1/1
1/1
1/1
● Suitable / available or according to the specified standard
* Not for ROK product variant
Functions
Industrial Ethernet interface 10/100 Mbps, TP, autocrossover
Configuration using the WBM, CLI or SNMP
MIB support
HTTP, HTTPS
SNMPv1, SNMPv2, SNMPv2c and SNMPv3
DHCP client
DHCP server for internal network
NAT (IP masquerading, NAT traversal, 1:1 NAT)
Port forwarding
DNS cache
Firewall (stateful packet inspection)
VPN with up to 20 connections
IPsec
OpenVPN client to SINEMA Remote Connect

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals