SCALANCE network components
4.8 SCALANCE S Industrial Security Appliance
Industrial Ethernet
System Manual, 09/2019, C79000-G8976-C242-10
267
S615
SC632-2C
SC636-2C
SC642-2C
SC646-2C
On site display (Set button)
C-PLUG slot
● Suitable / available or according to the specified standard.
Functions
The following table indicates the functions provided by the individual devices:
S615
SC632-2C
SC636-2C
SC642-2C
SC646-2C
Configuration with WBM, CLI or SNMP
MIB support
HTTP
SNMPv1, SNMPv2 and SNMPv3
SysLog
DHCP client
DHCP server (internal network)
Static IP routing
NAT/NAPT
Firewall (Stateful Packet Inspection)
Max. firewall data throughput
100 Mbps
600 Mbps
600 Mbps
600 Mbps
600 Mbps
IPsec support
-
-
Max. number of VPN connections
20
-
-
200
200
Max VPN data throughput
35 Mbps
-
-
120 Mbps
120 Mbps
Softnet security client
Connection to SINEMA Remote Connect via VPN
● Suitable / available or according to the specified standard.
4.8.5 Interfaces
The SCALANCE S modules have the following connectors or interfaces:
Device
Total number of
available ports
Twisted pair
Fiber-optic cables
Combo ports
100/1000 Mbps
10/100 Mbps
10/100/1000 Mbps
1000 Mbps
S615
5
5x RJ45
-
-
-
SC632-2C
2
1)
-
Max. 2x RJ45
-
2x SFP
SC636-2C
6
1)
-
Max. 6x RJ45
-
2x SFP
SC642-2C 2
1)
- Max. 2x RJ45 - 2x SFP
SC646-2C
6
1)
-
Max. 6x RJ45
-
2x SFP
1)
Of which 2 are combo ports