EasyManuals Logo

Siemens SIMATIC NET System Manual

Siemens SIMATIC NET
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #143 background imageLoading...
Page #143 background image
SCALANCE network components
4.5 SCALANCE X Industrial Ethernet Switches
Industrial Ethernet
System Manual, 09/2019, C79000-G8976-C242-10
143
4.5.6.2 Characteristics
The individual devices have the characteristics shown in the following table:
XB004-1
XB004-1LD
XB005
XB008
XB004-2
XB004-1G
XB004-1LDG
XB005G
XB008G
Gigabit Ethernet
-
-
Diagnostics LED
Power supply
24 V DC
24 V AC (50/60 Hz) - -
● Suitable / available or according to the specified standard
4.5.6.3 Interfaces
Device
Twisted pair
Fiber-optic cables
10/100 Mbps
10/100/1000 Mbps
100 Mbps
1000 Mbps
Max. segment length / km
XB004-1
4x RJ45
-
1x SC, multimode
-
4* / 5**
XB004-1LD
4x RJ45
-
1x SC, single-mode
-
26***
XB004-2
4x RJ45
-
2x SC, multimode
-
5
XB005
5x RJ45
-
-
-
-
XB008
8x RJ45
-
-
-
-
XB004-1G
-
4x RJ45
-
1x SC, multimode
0.75
XB004-1LDG - 4x RJ45 - 1x SC, single-
mode
10
XB005G
-
5x RJ45
-
-
-
XB008G
-
8x RJ45
-
-
-
* With a cable cross-section of 50 µm
** With a cable cross-section of 62.5 µm
*** With a cable cross-section of 9/125 μm; attenuation ≤ 0.5 dB/km at 1310 nm
4.5.6.4 Article numbers
Device
Description
Article number
SCALANCE XB004-1 4x 10/100 Mbps RJ45 ports electrical,
1x 100 Mbps SC port optical (multimode,
glass), up to max. 5 km
6GK5004-1BD00-1AB2
SCALANCE XB004-1LD 4x 10/100 Mbps RJ45 ports electrical,
1x 100 Mbps SC port optical (single-mode,
glass), up to max. 26 km
6GK5004-1BF00-1AB2

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals