SCALANCE network components
4.7 SCALANCE M industry router
Industrial Ethernet
254 System Manual, 09/2019, C79000-G8976-C242-10
4.7.5.2 Features and functions
Features of the basic devices and modules
The basic devices have the features listed in the table:
Suitable for module TS Module Modem
TS Module ISDN
TS Module RS-232
TS Module GSM
or
Router at WAN port
Number and type of the LAN interfaces 1x RJ45 port 2x RJ45 port
Number and type of the LAN interfaces
The modules have the characteristics shown in the following table:
Number and type of the
LAN interfaces
1x RJ11 socket 1x RJ11 socket 1x D-sub male
connector,
1x SMA female
Modules are supplied with power via the basic device
Functions of the devices
● Configuration via TIA Portal V11 and WBM. The TS adapter IE basic can also be used
with the standalone software TeleService as of V6.1 SP2 or with the SIMATIC Manager
● Remote maintenance via the telephone network
● Sending e-mails via an outgoing modem connection to a dial-in server.
● Internet access by establishing a connection to an Internet service provider.
● Access only after authentication with user name and password. Up to 8 users can be
configured.
4.7.5.3 Article numbers
Basic device without its own WAN interface
TS Adapter IE Ad-
Basic device with its own WAN interface and two
6ES7972-0EA00-0XA0
Modem for the analog telephone network
Terminal adapter for the ISDN network
Module for connection of an external modem
Wireless modem for the GSM/GPRS network